Insulating Glass Unit
Heated Insulating Glass Unit / For Freezers / Twin Thermo Glass
Thermal InsulationCondensation Prevention
Space-Saving High Insulation
- Thinner Air Layer
- We offer argon gas, which has better insulation performance than air, and even higher‑performance krypton gas as gases for the insulating layer, to meet your specific requirements.
| Air 12mm | Argon 10mm | Krypton 6mm | |
| Thermal transmittance (W/m2·K) | 2.89 | 2.80 | 2.78 |
- Multi‑Layering with Heat Mirror
- Even when further multi‑layering is required for higher insulation performance, multi‑layering using Heat Mirror keeps additional thickness and weight to a minimum, as only the air layer is added.

Heated Type
- Uniform Heating
- Because the heated type uses a surface heater, the entire surface heats evenly, quickly removing condensation across the whole surface (electrode areas do not generate heat. For the perimeter, where the influence of spacers is greater, we recommend the use of cord heaters).

- Stable Inorganic Heating Element
- Inorganic materials are used for the heating element, providing high stability and reliability even under changing operating conditions.
- High Efficiency
- The heating surface coating is designed with low emissivity to reduce heat transfer into the refrigerated space, improving insulation performance and warming the condensation surface efficiently.
- RoHS Compliant
- Lead‑free solder and electrode paste are used for the heated glass, and the product complies with RoHS regardless of whether the heated specification is selected.
Specifications / Precautions
Minimum dimensions: 180×350mm
Maximum dimensions: 2,400×3,200mm
(HM spec): 1,800×3,200mm
Maximum weight: 350kg
Total thickness: 18–52mm
- Argon and krypton gases are inert gases (colorless, odorless, and non‑toxic).
- The values shown are in‑house calculated results based on simulations.
- This product may fall under Japan’s PSE (Electrical Appliance and Material Safety) Law. Since it is supplied as a built‑in component, please obtain PSE certification for the final assembled product.
- Please also read the precautions for Twin Glass.